MODELING AND DYNAMIC SIMULATION OF AN AIR COOLED STEAM CONDENSER IN A COMBINED CYCLE POWER PLANT

 

R. Aguilar-Alderete, F. Sánchez-Silva, I. Carvajal-Mariscal

 

 

  • Air-cooled steam condensers avoid using 90 percent of water resources in power plants.

  • MATLAB/SIMULINK software for processes simulation

  • Procedure of dynamic simulation to analyze a system

  • Operation conditions effects on air cooled steam condenser backpressure

  • Transients analysis in an air cooled steam condenser